italiano

DataSafe Noir™ Energy Storage System

DataSafe Noir™ is a high-density lithium energy storage system engineered for modern data center power environments. Designed for modern UPS applications, DataSafe Noir™ energy system delivers predictable performance under dynamic load conditions while supporting compact megawatt-scale deployment.

As data centers increase in density and rely on increasingly variable AI-driven workloads, chemistry, runtime, and footprint no longer provide enough insight into how systems will perform under stress. The real challenge is maintaining predictable system behavior under dynamic operating conditions.

Richiedi un preventivo
seleziona la scheda delle specifiche di un prodotto

Control how power behaves under stress

DataSafe Noir™ energy storage system is engineered for predictable performance in high-density environments where load variability, deployment speed, and operational reliability are critical. Designed as an integrated system platform rather than a standalone battery solution, the platform supports predictable deployment, streamlined integration, and stable operation during commissioning and validation. A layered safety architecture with redundant safeguards at cell, module, and system levels supports controlled system behavior during abnormal operating conditions.

 

  • High-density lithium energy storage system for three-phase UPS applications
  • Up to 600 kW output per cabinet for 5 min end of life (EOL), depending on system configuration and conditions
  • Modular design supports up to 3 MW per UPS (configuration dependent)
  • Compact deployment footprint for high-density UPS environments
  • High-rate lithium iron phosphate (LFP) chemistry
  • Multi-level BMS architecture with integrated monitoring and protection
  • Layered protection architecture with redundant safeguards at cell, module, and system levels
  • CAN / RS485 and dry-contact UPS communications support
  • Designed for scalable deployment and predictable system integration
  • UL1973 certified and tested to UL9540A for modern data center compliance and safety requirements

Specifiche del prodotto

Dai un'occhiata alle seguenti DataSafe Noir™ specifiche di prodotto:

Applicazione

Gruppi di continuità industriali

Centri elaborazione dati

Tecnologia/Chimica

Ioni di litio

Capacità (min) - standard Europa

120

Capacità (max) - standard Europa

120

Capacità standard Europa

500kW

Capacità (min) - standard USA

120

Capacità (max) - standard USA

120

Tensione (min)

512

Tensione (max)

614

Potenza in uscita kW (Min)

500KW / 5min / 1.67Vpc / 77F

Potenza in uscita kW (Max)

600KW / 5min / 1.67Vpc / 77F

Caratteristiche di comunicazione

CAN bus

Ethernet

RS 485