Alpha logo

Alpha 8 Port Aggregator

For iDAS, indoor small cell and WiFi network equipment that consume more than 100 Watts of power, Alpha’s Aggregator safely enables remote line powering over copper cable.

select a product's specifications tab

By combining the unit with products from Alpha’s eLimiter™ family, the Aggregator meets the requirements for NEC Class 2 safety, enabling service providers to use conventional cable to remotely power the equipment. Class 2 compliance eliminates the need for conduit, licensed electricians and remote batteries, significantly improving the business case for the service provider.

The Aggregator can terminate up to four (4) or eight (8) NEC Class 2 circuits, combining them into a single 48V bulk output of up to 400 or 800 Watts. The unit is extremely compact, and can be either rack or wall mounted. It is a true front access device with all the user connections residing on the front face plate of the unit.

  • Aggregates up to four (4) or eight (8) NEC Class 2 inputs into a single, 48Vdc bulk output
  • When deployed in conjunction with Alpha’s eLimiter™ product family, meets the requirements for Class 2 circuits, even for remote devices that consume more than 100W of power
  • Enables remote powering of iDAS, indoor small cells and WiFi networks
  • Dramatically reduces CAPEX by eliminating the need for conduit and certified electrical technicians
  • Results in lower OPEX by eliminating the requirements for batteries at the remote sites
Request a Quote

Product Specification

Take a look at the following 8 Port Aggregator product specification:

Product Type

Indoor Remote Power Systems

Application

Passive Optical LANs

Central Offices / Switching Centers

Private 5G Networks

Input Voltage

48Vdc Nominal (x8 Class 2 Inputs)

Output Voltage

48Vdc Nominal

Output Power

≤800W

Efficiency

>98.5%

Dimensions H x W x D (inches)

1.72 x 10.83 x 8.85

Dimensions H x W x D (mm)

43.6 x 275 x 224.8

Net Weight (lb)

6

Net Weight (kg)

2.7

Temperature

Convection cooling: -40 to 45°C (-40 to 122°F) single unit operation only or separated by 76mm (3”) spacing in all dimensions / Forced air cooling: -40 to 65°C (-40 to 149°F) with minimum cabinet air flow of 200LFM

Humidity

0 to 95% RH non-condensing

Elevation

-500 to 2800m (-1640 to 9186ft)

Heat Dissipation

<37.5 BTU per hour

Connections

Input: 8x 2-position plug in terminal block (12-30AWG) / Output: 1x 2-position plug in terminal block (10-30AWG) / Alarm: 1x 3-position plug in terminal block (16-28AWG) / Chassis Ground: Accepts 1⁄4” - 5⁄8” center to center, dual hole terminal lug, max width 0.7” (18mm)

Safety

CSA/UL/IEC 62368-1 Edition 2.0 (2014)

EMC

ETSI 300 386